- BlackBerry® Enterprise Server 4.1
- BlackBerry® Enterprise Server Resource Kit
- DT 892086
Microsoft® Remote Procedure Call (RPC) Security Patch MS10-066 and MS10-084 causes the BlackBerry® Enterprise Server User Administration tool to stop functioning. The BlackBerry User Administration service is still running, but communication to the service with the BlackBerry Enterprise Server User Administration tool is disrupted when the RPC patch is installed.
The BlackBerry Enterprise Server User Administration tool commands fail with the following error:
[12:38:58] BESUserAdmin::main - Log Start
[12:38:58] BESUserAdmin::main - Error running client. Please check the:
a. BlackBerry User Administration Service is running
b. Correct network address (or computer name) of where the server is running (i.e. -n <network address>)
c. Correct BES instance to administer (i.e. -b <BES instance>)
A new RPC event is also created in the application log of the Windows® Event Log™:
Event Type: Warning
Event Source: RPC
Event Category: None
Event ID: 31201
Date: 21/09/2010
Time: 11:59:40 AM
User: N/A
Computer: BES06
Description:
Application BESUserAdminClient -p <PWD> -it_policies -n BES06 with process id 5784 has failed to complete a COM/RPC call because of an invalid message from server.
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp .
This is a previously reported issue that is being investigated by our development team. No resolution time frame is currently available.
Disclaimer
By downloading, accessing or otherwise using the Knowledge Base documents you agree:
(a) that the terms of use for the documents found at www.blackberry.com/legal/knowledgebase apply to your use or reference to these documents; and
(b) not to copy, distribute, disclose or reproduce, in full or in part any of the documents without the express written consent of RIM.
Visit the BlackBerry Technical Solution Center at www.blackberry.com/btsc.